High Voltage Insulating Mats

Santek In presents Electromat: highly recommended for total safety of workmen from electrical shock when working in or around environment like High Voltage Panels, Sub-station, Power Transformer Rooms, LT & HT Labs, near Busbars, near Control Panels etc.

https://i0.wp.com/www.electromat.in/images/header.png?resize=529%2C259

Safety from electrical shock is required for workmen whether they are involved in Electricity Generation, Transmission, Distribution or its use.

There are distinct features that set Electromat – High Voltage Insulating Mats apart from the REST whether they are Traditional Rubber mats or any other kind of synthetic mats.

 

Features & Specifications

1. Specifications
S.NO. Characteristics Standard Values
1. Thickness 2.mm   2.5 mm   3.0 mm
2. Roll Length 20 mtr. 15 mtr.   15 mtr.
3. Tensile Strength (N/MM2) 15 15   15
4. Elongation (%) 250  250   250
5. Insulation resistance with water at 500 V 1,000,000 M Ω 1,000,000 M Ω 1,000,000 M Ω
6. Leakage Current at 11 Kv 10 mA 10 mA 10 mA
7. Ac Di Electric Strength 30 Kv 45 Kv 65 Kv
8. Ac Proof Voltage 10 Kv should withstand for 1 Min. 22 Kv should withstand for 1 Min. 36 Kv should withstand for 1 Min.
9.   Flame retardance 5.0 Sec    5.0 Sec.   5.0 Sec.
Effect to Acid, Alkali, Diesel & Transformer OilAcid: Tensile Str. (N/MM2) Elong. (%) % Change from Original Value % Change from Original Value Tensile % Change from Original Value
10. Alkali: Tensile Str. (N/MM2) Elong. (%) Diesel: Tensile Str. (N/MM2) Elong. (%) T.Oil: Tensile Str. (N/MM2) Elong. (%) Tensile Strength
20% Elongation
20%
Strength 20%
Elongation 20%
Tensile Strength 20% Elongation
20%
11. Ageing Properties at 70±1ºC for 168 hrs.Tensile Strength

Elongation (%)

% change fromOriginal Value

T.S. 25%

% change from OriginalValue

T.S. 25%
E 25%

% change for OriginalValue

T.S. 25%

2. TYPICAL FEATURES:-
  1. Embossing: Anti-Skid without metallic derivatives
  2. Recommended thickness & Voltage:-
    SI.
    No.
    Class/User
    Voltage’s
    Recommended
    Thickness (mm)
    1. A/0 to 3.3 Kv 2.0
    2. B/3.3 to 11 Kv 2.5
    3. C/11 to 33 Kv 3.0
  3. Standard width is 1 meter but can be increased up to 2 meters .
  4. Material PVC Elastomer.
  5. Can be pasted at the front and rear side of the control panels and other electrical installations.
  6. The mat can be welded by hot gas welding with filler material, method by making “V” grove cut at joints with suitable welding cord of similar material.